Overview
The Report Settings page in the backend allows you to configure how inspection reports are generated, displayed, and sent to customers. These settings help ensure that reports meet your company’s formatting, content, and delivery preferences.
🧾 Accessing Report Settings
You can access these options by navigating to:
Backend Settings > Inspections > Report Settings
This page is broken out into three sections; Inspection Summary, Cover Letter, and Default Settings.
⚙️ Sections in Report Settings
📋 Inspection Summary
Configure if, and how, the inspection summary appears on your inspection reports. Additional deficiency configurations available here as well. Available options:
Deficiency Photos: Exclude Prior Deficiency Photos – Remove photos of previously noted deficiencies from the current report.
Enable Inspection Summary – Add a high-level summary table to the report.
Enable Inspection Summary for Individual Reports – When an individual report is generated, the inspection summary will be displayed.
Print Primary Technician on Multi-Technician Reports – By default, when a multi-tech inspection report is generated, the technician information is not displayed in the report header. If enabled, the Primary technician's name and additional credentials (if added at the technician-level) will print on the header of the reports just like reports with only one technician.
Print Deficiencies at Beginning of Report – List deficiencies before all other sections, previously listed at the end of the report.
Separate Suppression from Sprinkler Summary – Create distinct sections within the summary table for suppression and sprinkler system results.
Separate General from Sprinkler Summary – By default, when the Inspection Summary is enabled, the General Question and Sprinkler System details prints in the same section on the summary table. If this flag is enabled, when a sprinkler report is generated, the general question details print on a separate section of the summary table.
Exclude Technicians from Inspection Summary – Removes the Technician column from the summary table.
English Inspection Summary – Customize the text that prints at the top of the summary table.
✉️ Cover Letter
Add a cover letter to reports to provide a brief overview before the detailed results.
You can:
- Enable/disable the cover letter.
- Upload a Cover Letter Signature.
- Customize the text for:
- All-Pass Reports
- Reports with Deficiencies
🛠 Default Settings
Define the default behavior and appearance for all generated inspection reports, including:
- Include Display Name for External Forms & Backflows – When enabled, the display name prints on the report as opposed to the user-added name that is added when a backflow is added at the building-level and when adding external forms to an inspection.
- Show Deficiency Photos as Thumbnails – Renders deficiency photos as a compact gris of thumbnails, each linking to its full-size photo.
- Send Reports by Email from Inspect Point – When enabled, the inspection reports are sent through the backend. When a user clicks 'Send to Contacts' a module appears with Emails: Contains the building's report contact(s), Subject, Email Template, and a preview on the report PDF. Once sent, the email comes from noreply@inspectpoint.com. but if your customer responds to the email, it will go to whoever the backend user's email that sent the report. If left off, when 'Send to Contacts' is selected, this will open your computer's email client and is sent outside of Inspect Point from your email.
- Report Email Template – The email sent to your customers when a report is sent though Inspect Point.
-
Automatically Generate Inspection Reports – Inspection reports will automatically generate upon submission from the field.
-
User Advanced Send-Back Report Options – Requires the report auto-generate flag above. When enabled, the technician chooses exactly which reports are generated. Once enabled, additional setting options become available under a Send-Back Report Options section.
- Generate Full Report
- Generate Individual Reports
- Generate Separate Backflow Reports
- Generate Joint Commission Report
- Use Separate EP Codes Report
- Email Technician on Auto-Generate
-
User Advanced Send-Back Report Options – Requires the report auto-generate flag above. When enabled, the technician chooses exactly which reports are generated. Once enabled, additional setting options become available under a Send-Back Report Options section.
- Default Report Language – The default language will display on the report. If another language is enabled in your instance, you can override the language for a specific report on the corresponding inspection detail screen.
-
Image Resolution Size – Larger image resolution sizes will result in much larger PDFs and slower report generation.
- Higher image resolutions produce clearer images but increase PDF size and generation time.
- Inspection Report Display Name – Inspection report display names appear on your Inspection Reports tab, as well as in the Customer Portal.
- Report Date Format – Choose the default report date format. By default, the format is MM-DD-YYY.
- Inspection Date Source – Control which date is displayed on your inspection reports. This determines the “inspection date” shown to your customers.
Additional Info:
When updating fields such as Display Name or the Report Email Template, use placeholders like {{ building_name }}, {{ report_link }}, and {{ frequency }} to help clarify details at a glance.
Comments